Warning: Attempt to read property "alternativas" on null in /home/wwwalmotelecom/public_html/wp-content/plugins/calculo-de-despacho-via-starken-para-woocommerce/calculo-de-despacho-via-starken-para-woocommerce.php on line 299

Warning: foreach() argument must be of type array|object, null given in /home/wwwalmotelecom/public_html/wp-content/plugins/calculo-de-despacho-via-starken-para-woocommerce/calculo-de-despacho-via-starken-para-woocommerce.php on line 299
L4TNF-PS – ALMO-TELECOM
Dada la alta demanda de equipos y accesorios te recomendamos consultar por disponibilidad de stock antes de comprar
1

Cart

L4TNF-PS

Conector N Hembra para cable Heliax 1/2 LDF4-50A

Precio no incluye IVA

$28.350

1 hay existencias

Añadir a lista de deseos Consulta al experto
SKU: L4TNF-PS Categoría:

Descripción

Conector N Hembra para cable Heliax 1/2 LDF4-50A

Product Classification

Product TypeWireless and radiating connector
Product BrandHELIAX® | Positive Stop™

General Specifications

Body StyleStraight
Cable FamilyLDF4-50A
Inner Contact Attachment MethodCaptivated
Inner Contact PlatingSilver
InterfaceN Female
Mounting AngleStraight
Outer Contact Attachment MethodRing-flare
Outer Contact PlatingTrimetal
PressurizableNo

Dimensions

Length73.41 mm | 2.890 in
Diameter22.35 mm | 0.880 in
Nominal Size1/2 in

Electrical Specifications

3rd Order IMD at Frequency-116 dBm @ 910 MHz
3rd Order IMD Test MethodTwo +43 dBm carriers
Insertion Loss Coefficient, typical0.05
Average Power at Frequency0.6 kW @ 900 MHz
Cable Impedance50 ohm
Connector Impedance50 ohm
dc Test Voltage2000 V
Inner Contact Resistance, maximum2 mOhm
Insulation Resistance, minimum5000 mOhm
Operating Frequency Band0 – 8800 MHz
Outer Contact Resistance, maximum0.3 mOhm
Peak Power, maximum10 kW
RF Operating Voltage, maximum (vrms)707 V
Shielding Effectiveness-130 dB

Return Loss/VSWR

Frequency BandVSWRReturn Loss (dB)
50–1000 MHz1.02338.89
1010–2200 MHz1.02936.90
2210–3000 MHz1.04632.96
3010–4000 MHz1.07428.95
4010–6000 MHz1.11925.01

Mechanical Specifications

Attachment Durability25 cycles
Connector Retention Tensile Force889.64 N | 200.000 lbf
Connector Retention Torque5.42 N-m | 47.998 in lb
Insertion Force66.72 N | 15.000 lbf
Insertion Force MethodMIL-C-39012C-3.12, 4.6.9
Interface Durability500 cycles
Interface Durability MethodIEC 61169-16:9.5
Mechanical Shock Test MethodMIL-STD-202, Method 213, Test Condition I

Environmental Specifications

Operating Temperature-55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature-55 °C to +85 °C (-67 °F to +185 °F)
Attenuation, Ambient Temperature20 °C | 68 °F
Average Power, Ambient Temperature40 °C | 104 °F
Corrosion Test MethodMIL-STD-1344A, Method 1001.1, Test Condition A
Immersion Depth1 m
Immersion Test MatingUnmated
Immersion Test MethodIEC 60529:2001, IP68
Moisture Resistance Test MethodMIL-STD-202F, Method 106F
Thermal Shock Test MethodMIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
Vibration Test MethodIEC 60068-2-6
Water Jetting Test MatingUnmated
Water Jetting Test MethodIEC 60529:2001, IP66

Packaging and Weights

Weight, net89.63 g | 0.198 lb